Our footprint
What this site causes: the server, from the electricity we measure on the machine itself, and the visits, estimated from the data the site sends. Next to it, the CO₂e from the Deeds for the same days.
This is the whole server, not only this site. Our Minecraft server and a few private projects run on it too.
26 October 2026 to 24 November 2026, 30 days
What the site caused
- Server, estimated
- 7.7 kg
- Visits, estimated
- 39 g
- Page views
- 6,142
plus 2,895 by programs
- Data sent
- 348.2 MB
- Per page view
- 46.4 kB
5 mg estimated
The server: calculated from the electricity we measure on the machine itself (details below). Where a day was not measured and Scaleway has an estimate, that stands in. Scaleway's method, which ours follows
The server has an estimate for 29 of 30 days so far. That is why there is no combined total.
The visits: estimated with CO2.js (Sustainable Web Design v4) from the data the site sent, for the networks and devices on the way, with the world average grid because we do not know where visitors are. The data centre is already in the server figure and is not counted twice.
348.2 MB sent in 84,843 responses. Only daily totals per version and kind of page are counted: no address, no cookie, no single page.
A page view is every page the site delivered. Search engines, link previews and other programs are recognised by their user agent and counted apart. A program that pretends to be a browser counts as a person. People are not counted. Per page view means: the data sent to people, divided by their page views.
CO₂e per day
Highest bar: 292 g
- Server
- Visits
Show as a table
| Day | Server | Visits |
|---|---|---|
| 26 Oct | 248 g | 546 mg |
| 27 Oct | 248 g | 510 mg |
| 28 Oct | 251 g | 228 mg |
| 29 Oct | 263 g | 275 mg |
| 30 Oct | 270 g | 14 g |
| 31 Oct | 286 g | 322 mg |
| 1 Nov | 279 g | 1 g |
| 2 Nov | 272 g | 405 mg |
| 3 Nov | 275 g | 519 mg |
| 4 Nov | 277 g | 980 mg |
| 5 Nov | 277 g | 758 mg |
| 6 Nov | 279 g | 415 mg |
| 7 Nov | 280 g | 1 g |
| 8 Nov | 261 g | 890 mg |
| 9 Nov | 248 g | 971 mg |
| 10 Nov | 286 g | 739 mg |
| 11 Nov | 250 g | 677 mg |
| 12 Nov | 246 g | 1 g |
| 13 Nov | 244 g | 662 mg |
| 14 Nov | 238 g | 731 mg |
| 15 Nov | 226 g | 904 mg |
| 16 Nov | 228 g | 840 mg |
| 17 Nov | 227 g | 1 g |
| 18 Nov | 243 g | 1 g |
| 19 Nov | 290 g | 983 mg |
| 20 Nov | 290 g | 1 g |
| 21 Nov | 291 g | 1 g |
| 22 Nov | 291 g | 2 g |
| 23 Nov | 290 g | 2 g |
| 24 Nov | – | 1 g |
How much electricity the server draws
We measure this ourselves. A small program on the server reads the power meter of the whole machine every 5 seconds, next to the processor's own energy counters, and adds it up hour by hour. The CO₂e of the server above is calculated from these kilowatt-hours.
26 October 2026 to 23 November 2026, 29 days
- Electricity
- 32.4 kWh
- Average draw
- 47 W
- Highest draw
- 78 W
All 29 days are measured.
Of the measured electricity, the processor and memory used 27.7 kWh (exact energy counters) and everything else in the machine 4.72 kWh (disks, network card, board, fans).
| Part | CO₂e, estimated |
|---|---|
| Electricity in use: kWh × 1.45 (data centre overhead, PUE) × 44 g/kWh (French grid) | 2.1 kg |
| Building the server: 410 kg spread over 6 years | 5.4 kg |
| Building the data centre: a share by power | 163 g |
| Together | 7.7 kg |
Depending on where in the ranges below the true values lie, the total is between 5.5 kg and 10.5 kg.
What we assume
| Assumption | Used | Range | Where it comes from |
|---|---|---|---|
| Data centre overhead (PUE) | 1.45 | 1.44–1.45 | Scaleway's reference values. Which Paris zone our Dedibox stands in is not stated, the candidates are 1.44 and 1.45. |
| French grid, CO₂e per kWh | 44 g | 44–56 g | Scaleway's reference values (Ember). Its worked examples use 56 g. |
| Building the server, CO₂e | 410 kg | 263–567 kg | Boavizta, for our processor, memory and disks, without the end of life. |
| Building the data centre, CO₂e per kWh | 5 g | 0–10 g | Scaleway's worked example, scaled to the measured power. It is not about our hall, so the range is wide. |
Not included, because we cannot measure it: the network, shared management servers, spare hardware and offices that Scaleway adds on top in its own method. The visitors' devices and networks are in the visits figure.
What runs on the server
Several virtual machines share this server. Here is how much of the server's CO₂e we attribute to each machine.
| Machine | Share of the server | CO₂e, estimated | Processor work | Memory |
|---|---|---|---|---|
| Minecraft server 29 days with figures | 38% | 2.9 kg | 37% | 38% |
| Elpia and other web apps 29 days with figures | 19% | 1.4 kg | 18% | 19% |
This is an estimate, not a measurement. About 88% of the server's CO₂e does not depend on what runs: building the hardware and the data centre, and the electricity the machine draws even when idle. That part is split by reserved memory, the rest by the processor work each machine did. Days with fewer than 6 hours of usage reports, or without a server figure, are left out. The machines do not add up to the whole server: what the host itself uses and what stays free is not listed here.
How much of the electricity is idle draw (55%) follows from 710 measured hours with different load.
CO₂e from the Deeds in the same days
Grouped like on the impact page, and only projects with a CO₂e figure.
In these days nothing with a CO₂e figure was bought or growing.
Suggestion for Oct 2026
Server and visits caused an estimated 7.6 kg in this month.
These projects from the catalog have a CO₂e figure at least that large. A Deed there does not undo the emissions. It finances something that is documented with a receipt.
1 × tonne CO₂e: 1 t CO₂e, once, figure from the provider
1,120 Drops (€11.20)
1 × 100 kg CO₂e: 100 kg CO₂e, once, figure from the provider
1,905 Drops (€19.05)
Blue carbon from coastal restoration
1 × tonne CO₂e (estimated): 1 t CO₂e, once, rough estimate
1,936 Drops (€19.36)
Side by side, not offset: the two are never subtracted from each other. Elpia is not climate neutral, and paying for something good does not undo an emission.
The estimate for the single page you are on is at the bottom of every page, calculated in your browser.